BXCWG - LUGOL'S IODINE, 21-029
- MSDS: BXCWG
- Manufacturer: REMEL LIMITED PARTNERSHIP
- Product Name: LUGOL'S IODINE, 21-029
- National Stock Number: 6505-00N058358
Product Identification
Product ID:LUGOL'S IODINE, 21-029
MSDS Date:04/12/1993
FSC:6505
NIIN:00N058358
MSDS Number: BXCWG
Responsible Party
LENEXA, KS 66215
US
Emergency Phone: 800-255-6730
Info Phone: 913-888-0939
Cage: IO995
Contractor
Telephone: 800-447-3641
Cage: IO995
Ingredients
IODINE
CAS: 7553-56-2
RTECS: NN1575000
Fraction By Weight: 5.0%
OSHA PEL C 0.1 PPM
ACGIH TLV: C 0.1 PPM; 9495
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:NO Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:DANGER! POISON, MAY BE HARMFUL OR
FATAL IF SWALLOWED. MAY CAUSE IRRITATION TO SKIN, EYES AND
RESPIRATORY TRACT. AVOID BREATHING VAPOR AND EYE OR SKIN CONTACT.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:NONE SPECIFIED BY MANUFACTURER.
Medical Cond Aggravated by Exposure:PERSONS WITH PRE-EXISTING EYE, SKIN
OR RESPIRATORY DISORDERS MAY BE MORE SUSCEPTIBLE TO THE EFFECTS OF
THIS SUBSTANCE.
First Aid
First Aid:INHALATION: NOT APPLICABLE UNDER NORMAL CONDITIONS OF USE.
SEEK MEDICAL ASSISTANCE IF NECESSARY. EYE: WASH IMMEDIATELY WITH
COPIOUS AMOUNTS OF WATER FOR AT LEAST 15 MINUTES. CALL PHYSICIAN.
SKIN: WASH IMMEDIATELY WITH COPIOUS AMOUNTS OF WATER FOR AT LEAST
15 MINUTES. REMOVE CONTAMINATED CLOTHING. CALL PHYSICIAN.
INGESTION: CALL PHYSICIAN IMMEDIATELY.
Fire Fighting
Extinguishing Media:USE EXTINGUISHING MEDIA APPLICABLE TO SURROUNDING
FIRE CONDITIONS.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT .
Unusual Fire/Explosion Hazard:EMITS HIGHLY TOXIC FUMES OF IODINE.
Accidental Release
Spill Release Procedures:WEAR PROT CLOTHING & EQUIP SPECIFIED. WEAR
SCBA/RESPIRATOR W/APPRVD NIOSH/MSHA CARTRIDGES, IF NEC. CONTAIN
SPILL & FLUSH AREA WITH 1-5% SODIUM BISULFITE & H*2O SOLUTION.
ABSORB W/INERT MATERIAL, SCOOP UP & PLACE IN APPRVD HAZ WASTE
CNTNR.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:STORE AT ROOM TEMPERATURE.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.
Exposure Controls
Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN . NOT REQUIRED UNDER NORMAL CONDITIONS OF USE.
Ventilation:MECHANICAL EXHAUST, FUME HOOD.
Protective Gloves:CHEMICAL RESISTANT GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:PROTECTIVE APRON OR GOWN AS REQUIRED.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
SOLUBILITY IN WATER: INSOLUBLE (SOLUBLE IN AQUEOUS IODINE SOLN)
Chemical Properties
Boiling Pt:B.P. Text:185F,85C
Melt/Freeze Pt:M.P/F.P Text:114F,45C
Vapor Pres:1 @ 107F
Spec Gravity:4.93
Evaporation Rate & Reference:>1 (ETHER=1)
Solubility in Water:(SUPDAT)
Appearance and Odor:VIOLET-BLACK CRYSTALS, METALLIC LUSTER.
Percent Volatiles by Volume:100
Stability
Stability Indicator/Materials to Avoid:YES
STRONG REDUCING AGENTS, STRONG ACIDS; MAY REACT WITH METALS.
Stability Condition to Avoid:EXTREME HEAT.
Hazardous Decomposition Products:IODINE FUMES.
Disposal
Waste Disposal Methods:ENSURE COMPLIANCE WITH ALL LOCAL, STATE, AND
FEDERAL REGULATIONS OR CONTACT AN APPROVED AND LICENSED DISPOSAL
AGENCY.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.